Murrelektronik Xelity
The Murrelektronik Xelity managed switches run logiccloud Control in an LXC container on the device itself, so one device is both the network switch and the PLC runtime.
Supported devices
Section titled “Supported devices”All six variants are supported. The PN variants add Profinet.
| Device | Ports | Profinet | Protection |
|---|---|---|---|
| Xelity 4TX M GE | 4 × 1000 Mbit | — | IP20 |
| Xelity 4TX M GE PN | 4 × 1000 Mbit | Yes | IP20 |
| Xelity 6TX M GE | 6 × 1000 Mbit | — | IP20 |
| Xelity 6TX M GE PN | 6 × 1000 Mbit | Yes | IP20 |
| Xelity 8TX M GE | 8 × 1000 Mbit | — | IP20 |
| Xelity 8TX M GE PN | 8 × 1000 Mbit | Yes | IP20 |
Select your exact device type when you create the device in the logiccloud IDE.
Every variant runs on the same platform:
| Architecture | Memory | Cores | Container type |
|---|---|---|---|
ARM 32 (linux/arm/v7) | 1 GB | 2 | LXC |
Device processes
Section titled “Device processes”Three services can run on a Xelity beside the runtime. Only the first is installed automatically; the other two you enable yourself under Edit device processes.
| Service | Enabled | What it does |
|---|---|---|
| Edge license service | Always | Handles licensing on the device. |
| Debugging service | Optional | Lets you debug the running program online from the IDE. |
| OPC UA browsing service | Optional | Lets the IDE browse the OPC UA address space of the device. |
Install logiccloud Control
Section titled “Install logiccloud Control”1. Get the container
Section titled “1. Get the container”No Xelity container is linked from this documentation yet. Contact logiccloud support to obtain the correct container image for your device.
The other LXC devices publish theirs on the logiccloud downloads page — for example INSYS MRX and Perinet periMICA. This page will link the Xelity container once it is published.
2. Install the container on the device
Section titled “2. Install the container on the device”- Open the web interface of your Xelity switch and log in.
- Find the container management area of the interface.
- Upload the container image you received, and confirm the upload.
- Edit the container and configure its network, so that it reaches the internet
and is reachable from your network. On comparable devices this means setting:
- the network bridge or interface to use,
- the IPv4 address of the container — a free address in the same network as
the device, for example
192.168.1.21if the device is192.168.1.1, - the IPv4 netmask, for example
24, - the IPv4 gateway, which is normally the address of the device itself.
- Save the configuration, then apply or activate it.
3. Connect the device and install the runtime
Section titled “3. Connect the device and install the runtime”Once the container runs, open the installation interface at the container IP
you configured — 192.168.1.21 in the example above. From there you create the
device in the logiccloud IDE, connect it with its device token, and install the
runtime.
Follow the shared guide here: install logiccloud Control.